    ClinMax™ Human Soluble ROR1 ELISA Kit,PRO is a ready-to-use immunoassay kit, specifically designed to quantitate natural and recombinant human ROR1 that is present in biological samples, such as human serum, plasma, and cell culture supernatants. Our ClinMax™ ELISA Kit provides several benefits:
    1. Fully validation in biologic samples for detection range, sensitivity, inter- and intra-plate CV, recovery, dilution linearity, specificity, and matrix effects to ensure reliable results according to ICH M10 guideline.
    2. High-quality antibody pairs and protein standards, along with rigorous quality control, to guarantee consistent results across different batches.
    3. Simplified and straightforward protocols and ready-to-use reagents to save assay time.
  • Application

    The kit is developed for quantitative detection of natural and recombinant human ROR1 in serum, plasma and cell culture supernatants.

    It is for research use only.

  • Workflow
     ROR1 Workflow
    Key Features
    AnalyteSoluble ROR1
    Assay TypeSandwich-ELISA
    ReactivityHuman
    Sensitivity0.78125ng/mL
    Range0.78125 ng/mL-200 ng/mL
    Assay Time2hr
    Sample TypeCell Culture Supernatants, Plasma, Serum.
    Sample volume50 μL
    Format96-wells plate breakable into 12 x 8 wells strips

    Elevate your research experience with our Cytokine/Biomarker Detection Kits, where accuracy, reliability, and ease of use are converging to deliver exceptional results.

  • Storage
    Keep the unopened kit stored at 2-8 °C. Avoid using the kit beyond its expiration date. The opened kit should be stored per components table. The shelf life is 30 days from the date of opening.
Typical Data Please refer to DS document for the assay protocol.
 ROR1 TYPICAL DATA

For each experiment, a standard curve needs to be set for each microplate, and the specific OD value may vary depending on different laboratories, testers, or equipment. The following example data is for reference only. The sample concentration was calculated based on the results of the standard curve. The minimum detectable concentration of ROR1 is less than 0.78125 ng/mL.

Validation
Intra-Assay Statistics

Ten replicates of each of 4 samples containing different ROR1 concentrations were tested in one assay. Acceptable criteria: CV<10%.

 ROR1 INTRA-ASSAY STATISTICS
Inter-Assay Statistics

Five samples containing different concentrations of ROR1 were tested in independent assays. Acceptable criteria: CV<15%.

 ROR1 INTER-ASSAY STATISTICS
Recovery

Recombinant ROR1 was spiked into 3 human serum samples, and then analyzed. The average recovery of ROR1 for serum samples is 103.2%.

 ROR1 RECOVERY
Materials Provided
IDComponentsSize
CEA050-C01Pre-coated Anti-ROR1 Antibody Microplate1 plate
CEA050-C02Human ROR1 Standard20 μg×2
CEA050-C03Biotin-Anti-ROR1 Antibody Con. Solution400 μL
CEA050-C04Biotin-Antibody Dilution Buffer8 mL
CEA050-C05Streptavidin-HRP Con. Solution500 μL
CEA050-C06Streptavidin-HRP Dilution Buffer15 mL
CEA050-C0720× Washing Buffer50 mL
CEA050-C08Sample Dilution Buffer15 mL ×2
CEA050-C09Substrate Solution12 mL
CEA050-C10Stop Solution6 mL
  • Clinical and Translational Updates

Comments (0)


ETA de productos en stock: 2 días laborables

Price(EUR) : €600.00

Price(EUR) :


Promotion & Exhibitions



Drug Development Status

  • Number of Launched Drugs:0 Details
  • Number of Drugs in Clinical Trials:12 Details
  • Latest Research Phase:Phase 3 Clinical

Datasheet & Documentation

Request for DMF
DMF (Drug Master File)

Related Products

New Product Launch

Questions & Comments

This web search service is supported by Google Inc.

totop
Email
Correo electrónico
Fax
Fax
+1 888-377-6111
Address
Address
Lichtstrasse 35,4056 Basel, Switzerland

Dejar un mensaje