Product Details
Features
- Designed under ISO 9001:2015 and ISO 13485:2016
- Manufactured and QC tested under a GMP compliance factory
- FDA DMF filed
- Animal-Free materials
- Beta-lactam materials free
- Batch-to-batch consistency
- Stringent quality control tests
- No animal derived peptone and lactose used in production process.
Product Details
GMP Salt Active GENIUS™Nuclease is developed with ACRObiosystems' unique enzyme AI evolution platform based on wild-type Serratia marcescens endonuclease. It is capable of maintaining high specific activity to effectively degrade nucleic acids in any form across a broad salt concentration range (0-500 mM NaCl), especially high salt up to 500mM NaCl, which makes it suitable for nucleic acid removal in processes that of higher salt conditions. The enzyme is a non-specific nuclease with high specific activity, degrading single- and double-stranded nucleic acids in any form (single stranded, double stranded, linear, circular, and supercoiled). It hydrolyzes internal phosphodiester bonds present between the nucleotides to 5’- phosphorylated oligonucleotides of 3-5 bases in length.
Application
Elimination of nucleic acids from biologics, suitable for samples with 0-500 mM salt in presence of 5-10 mM Mg++
• clinical viral vaccine production
• clinical viral vector production for cell and gene therapy (CGT)
• Other clinical development and production usesPurity
>95% as determined by SDS-PAGE.
>95% as determined by SEC-HPLC.
Enzyme Activity
>250 U/μL
Host Cell Protein
<0.05 ng/µg of protein tested by ELISA.
Protease Activity
Negative
Sterility
Sterility testing was performed using the membrane filtration method in compliance with USP <71> and Ph. Eur. 2.6.1.
Mycoplasma
Negative
Endotoxin
Less than 10 EU/mg, tested by the LAL method in compliance with USP <85> and Ph. Eur. 2.6.14.
Formulation
Supplied as 0.2 μm filtered solution in 25 mM Tris, 500 mM NaCl, 5 mM MgCl2, pH7.5.
Contact us for customized product form or formulation.
Shipping
This product is supplied and shipped with dry ice, please inquire the shipping cost.
Storage
This product is stable after storage at:
- The product MUST be stored at -20°C or lower upon receipt;
- -20°C for 5 years under sterile conditions.
Customers Also Viewed
Performance Data
SDS-PAGE

The gel was stained with Coomassie Blue. The purity of the protein is greater than 95% (With Star Ribbon Pre-stained Protein Marker).
SEC-HPLC

The purity of GMP Salt Active GENIUSNuclease (Cat. No. GMP-NUES13) was greater than 95% as determined by SEC-HPLC.
Bioactivity
Specific activity for GMP Salt Active GENIUS™Nuclease is measured under standard assay conditions. The specific activity of GMP GENIUS Nuclease is >4.3E+05 unit/mg at 500 mM salt concentration (QC tested). One unit will digest sonicated salmon sperm DNA to acid-soluble oligonucleotides equivalent to a ΔA260 of 1.0 in 30 min at pH 8.0 at 37 °C, which corresponds approximately to complete digestion of 37 μg DNA.

GMP GENIUS Nuclease shows high specific activity.

The effect of Mg++ concentrations on Salt Active GENIUS™Nuclease activity. The Nuclease requires 5 mM Mg++ cations for optimal activity.
Bioactivity-Stability

The specific activity shows that GMP Salt Active GENIUS™Nuclease (Cat. No. GMP-NUSE13) is stable in different batches.

The specific activity shows that GMP Salt Active GENIUS™Nuclease (Cat. No. GMP-NUSE13) is stable at 37℃ for 21 days.
Customer Reviews Writing Reviews

Important Statement
MANUFACTURING SPECIFICATIONS
ACROBiosystems GMP grade products are produced under a quality management system and in compliance with relevant guidelines: Ph. Eur General Chapter 5.2.12 Raw materials of biological origin for the production of cell-based and gene therapy medicinal products; USP<92>Growth Factors and Cytokines Used in Cell Therapy Manufacturing; USP<1043>Ancillary Materials for Cell, Gene, and Tissue-Engineered Products; ISO/TS 20399-1:2018, Biotechnology - Ancillary Materials Present During the Production of Cellular Therapeutic Products.
ACROBiosystems Quality Management System Contents:
- Designed under ISO 9001:2015 and ISO 13485:2016, Manufactured and QC tested under a GMP compliance factory
- Animal-Free materials
- Materials purchased from the approved suppliers by QA
- ISO 5 clean rooms and automatic filling equipment
- Qualified personnel
- Quality-related documents review and approve by QA
- Fully batch production and control records
- Equipment maintenance and calibration
- Validation of analytical procedures
- Stability studies conducted
- Comprehensive regulatory support files
ACROBiosystems provide rigorous quality control tests (fully validated equipment, processes and test methods) on our GMP grade products to ensure that they meet stringent standards in terms of purity, safety, activity and inter-batch stability, and each bulk QC lot mainly contains the following specific information:
- SDS-PAGE
- Protein content
- Endotoxin level
- Residual Host Cell DNA content
- Residual Host Cell Protein content
- Biological activity analysis
- Microbial testing
- Mycoplasma testing
- In vitro virus assay
- Batch-to-batch consistency
ACROBIOSYSTEMS - LEGAL NOTICES FOR GMP GRADE PRODUCTS
1. PRODUCT USE RESTRICTIONS & PROHIBITIONS
- 1.1 ACROBiosystems ("ACRO") GMP grade products ("Products") are designed for research, manufacturing use or ex vivo use.
- 1.2 Products are NOT intended for diagnostic purposes or for direct or indirect administration into humans.
- 1.3 Purchaser shall not market, distribute, or resell Products obtained from ACRO without ACRO's prior written consent.
2. REVERSE ENGINEERING PROHIBITED & CONFIDENTIALITY
- 2.1 Purchaser shall not reverse-engineer, decompile, disassemble, sequence, analyze via bioinformatics, or otherwise attempt to discover the structure, sequence, composition, construction, manufacturing process, or any trade secret embodied in the Products. Purchaser shall not permit any third party to undertake such activities.
- 2.2 All specifications, data, and know-how related to the Products provided by ACRO are ACRO's confidential information and shall be protected accordingly.
3. LIMITED WARRANTY & DISCLAIMERS
- 3.1 ACRO warrants solely that Products will conform to their published specifications when used under normal, specified laboratory/manufacturing conditions and within their labeled expiration date. THIS IS THE ONLY WARRANTY PROVIDED.
- 3.2 Purchaser assumes ALL risk and responsibility for:
(a) Determining the suitability of Products for Purchaser's intended application(s).
(b) Obtaining any necessary regulatory approvals or intellectual property licenses for Purchaser's use.
(c) Compliance with all applicable laws, regulations (including but not limited to cGMP/GLP where claimed), and industry standards.
(d) Conducting all necessary quality control, safety, efficacy, and validation testing of Products within Purchaser's process or final product.
(e) Proper storage, handling, and use of Products according to ACRO's instructions.
- 3.3 ACRO EXPRESSLY DISCLAIMS ALL OTHER WARRANTIES, WHETHER EXPRESS, IMPLIED, STATUTORY, OR OTHERWISE, INCLUDING BUT NOT LIMITED TO: (A) WARRANTIES OF MERCHANTABILITY; (B) WARRANTIES OF FITNESS FOR A PARTICULAR PURPOSE; (C) WARRANTIES OF NON-INFRINGEMENT; AND (D) WARRANTIES ARISING FROM COURSE OF DEALING OR USAGE OF TRADE.
4. LIMITATION OF LIABILITY
- IN NO EVENT SHALL ACRO, ITS AFFILIATES, OR SUPPLIERS BE LIABLE FOR ANY OF THE FOLLOWING, HOWSOEVER ARISING (WHETHER IN CONTRACT, TORT (INCLUDING NEGLIGENCE), STRICT LIABILITY, STATUTE, OR OTHERWISE):
(a) LOST PROFITS, LOST REVENUE, LOST SAVINGS, LOSS OF USE, LOSS OF DATA, BUSINESS INTERRUPTION, OR ANY OTHER INDIRECT, INCIDENTAL, SPECIAL, PUNITIVE, OR CONSEQUENTIAL DAMAGES.
(b) ANY DIRECT DAMAGES, COSTS, OR EXPENSES EXCEEDING THE AMOUNT PAID BY PURCHASER FOR THE SPECIFIC PRODUCT(S) GIVING RISE TO THE CLAIM.
(c) DAMAGES ARISING FROM: (i) MISUSE, ABUSE, OR UNAUTHORIZED MODIFICATION OF PRODUCTS; (ii) USE BEYOND THE EXPIRATION DATE; (iii) IMPROPER STORAGE OR HANDLING; (iv) ACCIDENTAL DAMAGE; (v) FAILURE TO CONDUCT ADEQUATE VALIDATION OR TESTING BY PURCHASER; (vi) INFRINGEMENT CLAIMS RELATED TO PURCHASER'S USE; OR (vii) THE COST OF PROCURING SUBSTITUTE GOODS OR SERVICES.
(d) ANY PERSONAL INJURY, DEATH, OR DAMAGE TO TANGIBLE PROPERTY TO THE EXTENT PERMITTED BY LAW.
5. END USER ACKNOWLEDGEMENT & COMPLIANCE
- 5.1 By accepting, opening, or using the Products, the End User (Purchaser or its downstream recipient) agrees to be irrevocably bound by all terms herein.
- 5.2 End User explicitly acknowledges the Products are NOT FOR HUMAN ADMINISTRATION and agrees not to use them in any in vivo human application, directly or indirectly.
- 5.3 End Users unwilling to accept these terms must immediately: (a) cease all use; (b) notify ACRO or their supplier; and (c) return the unopened, unused Products. 5.4 ACRO reserves the right to audit End User's compliance with these restrictions upon reasonable notice
ACRO has the right, at its sole discretion, to modify, add or remove any terms herein without notice to Purchaser and/or End User. Any changes to these terms are effective immediately following the updating of such changes on ACRO’s website or published specifications or product-related documents