AAV3 Titration ELISA Kit (Fast)

Customer Reviews
Cat. No. / Size
Price
Qty
AAV-A003H-96tests
$670.00
ETA of in-stock products:2 business days

Product Details

  • Product Specifications

    Assay Type
    Sandwich-ELISA
    Analyte
    AAV3
    Format
    96T
    Regulatory Status
    RUO
    Sensitivity
    <2.62E+08 capsids/mL
    Standard Curve Range
    8.39E+09 capsids/mL-2.62E+08 capsids/mL
    Assay Time
    2 hr 20 min
    Suitable Sample Type
    For the detection and quantitative determination of AAV3 capsid titration in AAV gene therapy product preparation processing.
    Sample volume
    100 μL

  • Product Overview

    AAV3 Titration ELISA Kit (Fast) is based on the sandwich-ELISA method and is used to detect and quantitatively determine the AAV3 capsid titration in AAV gene therapy product winthin 2hr 20 min. The kit is designed to provide reliable solutions for the early development, production, and quality control of AAV gene therapy products.

  • Reconstitution

    Please see Certificate of Analysis for details of reconstitution instruction and specific concentration.

  • Storage

    1. Unopened kit should be stored at 2℃-8℃ upon receiving.

    2. Find the expiration date on the outside packaging and do not use reagents past their expiration date.

    3. The opened kit should be stored per components table. The shelf life is 30 days from the date of opening.

  • Materials Provided

    ID
    Components
    Size
    AAV03H-C01
    Pre-coated Anti-AAV3 Antibody Microplate
    1 plate
    AAV03H-C02
    AAV3 Standard
    5.03E+10 capsids
    AAV03H-C03
    HRP-Anti-AAV3 Antibody
    20 μg
    AAV03H-C04
    10×Washing Buffer
    50 mL
    AAV03H-C05
    2×Dilution Buffer
    50 mL
    AAV03H-C06
    Substrate Solution
    12 mL
    AAV03H-C07
    Stop Solution
    7 mL

  • ACRO Quality Management System

    1. QMS(ISO, GMP)
    2. Quality Advantages
    3. Quality Control Process

Customers Also Viewed

Performance Data

  • Typical Data 

    Please refer to DS document for the assay protocol.

     AAV3 TYPICAL DATA

    For each experiment, a standard curve needs to be set for each micro-plate, and the specific OD value may vary depending on different laboratories, testers, or equipments. The following example data is for reference only.

Validation
  • Dilution Linearity

    To assess the linearity of the assay, samples spiked with high concentrations of AAV3 were serially diluted with calibrator diluent to produce samples with values within the dynamic range of the assay.

     AAV3 DILUTION LINEARITY
  • Intra-Assay Statistics

    Three samples of known concentration were tested ten times on one plate to assess intra-assay precision.

     AAV3 INTRA-ASSAY STATISTICS
  • Inter-Assay Statistics

    Three samples of known concentration were tested in three separate assays to assess inter-assay precision.

     AAV3 INTER-ASSAY STATISTICS
  • Recovery

    Three AAV3 with different concentrations were tested to calculate the recovery rate.

     AAV3 RECOVERY
  • Specificity

    The specific binding of AAV-A003H to AAV1/2/3/5/6/8/9/dj serotypes was detected. The results showed that AAV-A003H only binds specifically to AAV3.

     AAV3 SPECIFICITY

    The specific binding of AAV-A003H to native/denatured AAV3 was detected. The results showed that AAV-A003H only binds specifically to native AAV3. (Denatured AAV3: 95℃ for 10min)

     AAV3 SPECIFICITY

Customer Reviews
Writing Reviews

Recent Advances

 
Drug Candidate Licensing
More
  • Basic Product Information
  • Product Details
  • Customers Also Viewed
  • Performance Data
  • Customer Reviews