My Cart

Human BCMA-coupled Magnetic Beads

Customer Reviews
Cat. No. / Size
Price
Qty
MBS-K004-2mg
$1070.00
MBS-K004-10mg (5mg X 2)
$3350.00
ETA of in-stock products:2 business days
Sub-Total$ 0

Product Details

  • Items
    Size 2mg
    Size 10mg (5mg × 2)
    Particle size
    2 μm
    2 μm
    Physical appearance
    Powder mixture
    Powder mixture
    Binding Capacity
    >267 pmol (40 μg) antibody/mg beads
    >267 pmol (40 μg) antibody/mg beads
    Formulation
    PBS, pH7.4, with 10% Trehalose
    PBS, pH7.4, with 10% Trehalose
    Reconstitution
    2 mL sterile deionized water (1 mg beads/mL)
    5 mL sterile deionized water (1 mg beads/mL)
  • Product Description

    The biotinylated BCMA protein was conjugated to streptavidin magnetic beads. This pre-coupled magnetic bead product can capture the anti-BCMA antibody from various assay systems. The beads are in uniform size, narrow size distribution with large surface area and unique surface coating, which can help you get the best performance and highly reproducible results. This Human BCMA-coupled magnetic beads will bring great convenience with minimum non-specific binding and developed protocols. This ready-to-use product could greatly save your time and hassle.

  • Application

    This product is intended for immunocapture, biopanning. This is a non-sterile product.

    * The Isotype control (Cat. No. SMB-B01) is sold separately.

  • Reconstitution

    See Certificate of Analysis (CoA) for detailed instruction.

  • Storage

    Upon receipt, please store the Beads at -20°C. The shelf life is 1 year at -20 °C. Once reconstitution, please aliquote and store under -70°C for no more than 3 months, and avoid repeated freeze-thaw cycles. Immediate use after reconstitution is highly recommended.

    Please avoid more than 3 freeze-thaw cycles once reconstitution, immediate use after reconstitution is highly recommended.

  • Assay Principles

    Antibody Purification:
    1. Resuspend the lyophilized beads by adding the buffer of choice.
    2. Add analyte to the suspension, mix and incubate to enable specific binding of the beads and the target protein.
    3. Magnetize beads, remove supernatant, and wash unbound protein fractions to capture target protein-bound beads.
    4. Wash, magnetize the beads and collect purified target protein for use in downstream applications.

    The magnetic beads technology makes use of the easy and efficient collection of beads in magnetic field to facilitate antibody purification in a simple workflow of “bind-wash-elute”. In contrast to common separation techniques, this method does not require columns or centrifugation, and is therefore ideal in high-throughput applications.

  • ACRO Quality Management System

    1. QMS(ISO, GMP)
    2. Quality Advantages
    3. Quality Control Process

Customers Also Viewed

Performance Data

  • Typical Data

     BCMA TYPICAL DATA

    Add BCMA pre-coupling magnetic beads into each well at a concentration of 1 mg/ml. 0.1 mg beads was added to each well. Then add increasing concentrations of anti-BCMA antibody to different wells. PE-labeled anti-human IgG Fc antibody was used for detection.

    Protocol
  •  BCMA TYPICAL DATA

    The binding curves between BCMA pre-coupling magnetic beads (Cat. No. MBS-K004) after different freeze-thaw cycles and anti-BCMA antibody. 0.1 mg of Beads (1 mg/mL, 100 μL) was washed three times and the supernatant was removed. 100 μL antibodies of the corresponding concentration (10 μg/mL-0.039 μg/mL) were added. Fluorescent labeled secondary antibody was added for detection (Routinely tested).

    Protocol

Customer Reviews
Writing Reviews

Recent Advances

 
Drug Development Progress
  • English Name:

    B-cell maturation protein

  • Category:

  • Approved Drugs:

    8 Details

  • Drugs in Clinical Trials:

    145 Details

  • Highest Development Stage:

    Approved

Drug Candidate Licensing
More
  • Basic Product Information
  • Product Details
  • Customers Also Viewed
  • Performance Data
  • Customer Reviews